Skip to content

Propex FAQ

← Back to FAQ Home

Propex

Heater Installation & Support

Getting Help

What should I do if my Propex heater is having issues?

Start with the troubleshooting answers below. If you are still stuck, reach out to our team in Fort Collins and we'll work through it with you. Call (970) 578-0791 (Monday through Friday, 8 AM to 5 PM) or email support@mountaintimecampers.com.

Include your name, email, and phone number, your heater model, a short description of what is happening, and these photos of your installation:

  • White sticker on the end of the unit
  • Combustion intake pipe (complete routing)
  • Combustion exhaust pipe (complete routing)
  • Propane regulator (remove the plastic cover for the photo if installed)
  • Heater unit itself
  • Fuel line and fittings
  • Large heated-air ducting from the heater to the vents

Photos help our tech team spot things that are hard to describe, so we can get you back to warm faster.

Where can I buy Propex heaters and add-ons?

Every Propex heater we carry is right here on our site. Each product page walks you through who it fits, what's in the kit, and the install docs.

You can also browse everything in our Propex heater collection. Need a part you don't see? Give us a call and we'll help you track it down.

What happens if my Propex heater needs a non-warranty repair?

If your heater needs a repair that isn't covered by warranty, we can walk you through the Propex Non-Warranty Repair Agreement.

Non-warranty repairs may apply when a heater is outside its warranty period, or when the issue isn't covered under warranty.

Before sending a heater in, please contact us at (970) 578-0791 or support@mountaintimecampers.com so we can figure out the right next step together.

Include your Propex model and a description of the issue. Photos of the heater, installation, wiring, and any fault-code lights help us a lot.

Understanding Your Heater

Which Propex heater is right for me?

The right pick depends on the size of your space, where you can mount it, and whether you want permanent or portable heat. Here's the quick rundown:

HS2000: 6,500 BTU, mounted inside. A favorite for camper vans and small to mid-size trailers.

HS2800: 9,500 BTU, mounted inside. Made for larger vans, bigger trailers, and colder-climate camping.

HS2211: 6,500 BTU, mounted under the vehicle. Great when you can't spare interior space, like teardrops and tight van builds. It needs a larger floor opening than the HS2000, and because it lives outside and takes on dirt and weather, it carries a 3-year warranty.

PS2000 Slimline: 6,500 BTU portable heat with no permanent install. Our top portable pick for truck campers, tents, hunting blinds, and ice fishing shelters.

PS2000 Portable Heater System: The original Pelican suitcase version, with an optional power bank.

Still not sure? Call us at (970) 578-0791 and we'll happily help you compare before you order.

Do I need a high altitude version of my Propex heater?

If you regularly camp above about 7,500 ft, it's worth it. For the HS2000, HS2800, and HS2211, choose the High Altitude option when you order, or add our High Altitude Modification service to a heater you already own.

The PS2000 Slimline and PS2000 suitcase already ship high-altitude modified, so there's nothing extra to add.

What is the difference between pipes, ducts, and tubing on a Propex heater?

Using the right words helps us get you faster, more accurate support. These three systems do different jobs and should never be swapped for one another.

Pipes (Combustion)

Propex combustion intake and exhaust pipe

The smaller corrugated pipes (22mm on the HS2000 and HS2211, 26mm on the HS2800) that connect to the combustion intake and exhaust fittings on the bottom of the unit. They must never be shorter than 1 meter (about 40 inches).

Ducts / Ducting (Cabin Air)

Propex heated cabin air ducting

The larger corrugated ducting (60mm on the HS2000 and HS2211, 76mm on the HS2800) that carries cabin air across the heat exchanger and delivers warm air back into your space.

Tubing (Propane)

Copper propane tubing for a Propex heater

The propane line from your regulator to the heater, usually 1/4 inch copper tubing. The heater's propane fitting is a 1/4" compression fitting, so the tubing must have an exact 1/4" outside diameter.

Not sure which part you need? Send us your heater model and we'll help you find it.

What is the warranty on my Propex heater?

Standard warranty coverage from purchase:

  • HS2000: 1 year
  • HS2800: 1 year
  • HS2211: 3 years (it lives under the vehicle and is built to handle dirt and weather)
  • PS2000 Slimline Portable Heater System: 1 year
  • PS2000 Suitcase Portable Heater System: 1 year

Want more peace of mind? We offer an optional 5-year extended warranty for Propex heaters purchased from Mountain Time Campers. It's a one-time fee.

You can add the extended warranty with your heater, or later, as long as the heater was bought directly from Mountain Time Campers and the original order is within one year of when you buy the coverage. If you add it later, you'll need to be the original purchaser and provide your original Mountain Time Campers invoice.

The extended warranty covers manufacturing defects of the Propex heater and the original thermostat sold with it. It does not cover accessories, or damage from misuse, improper installation, accidents, exposure to dust or moisture, improper wiring, normal wear and tear, or damage during travel.

Any repair attempt or work on the heater by anyone other than Mountain Time Campers will void the warranty. That includes removing the top case from the heater.

A big perk of our extended warranty: bench time for repairs is covered at 100%, no matter the issue. That includes time to test-run the heater on the bench or do a clean-out if needed. Replacement parts not covered under the warranty terms are still the customer's responsibility.

Shipping to and from Mountain Time Campers is the customer's responsibility. Warranty coverage is non-transferable and non-refundable.

Before sending a heater in for warranty service, please email support@mountaintimecampers.com or call (970) 578-0791 so we can send you the right next steps.

Installation Tips

Can I mount my Propex heater above floor level?

Yes, as long as the combustion intake, exhaust, heated-air ducting, and propane connections can all be routed correctly.

Mount the heater securely, in a spot where every connection can be made without restrictions or unsafe routing.

Pay special attention to the combustion intake and exhaust. These pipes must stay separate from the cabin air system and follow the Propex installation requirements.

Not sure your spot will work? Send us photos and measurements of the location along with your heater model, and we'll help you sort it out.

How does the thermostat work, and what do I need to know before connecting it?

Your Propex comes with a digital thermostat, so you can set an exact target temperature and let the heater cycle to hold it. On US-spec gas-only models, the digital thermostat also includes a 1 to 16 hour countdown timer.

⚠️ Important: Always connect the thermostat to the Propex unit before connecting 12V power. Thermostat first, then power. Doing it in the other order can blow the heater's internal fuse. Replacement 2A slow-blow fuses are available from us.

Can I extend the Propex thermostat harness?

Yes. Propex offers a way to extend the thermostat harness when the standard length won't reach your mounting spot.

Make sure every thermostat wiring connection is secure and protected from moisture and corrosion. If you need help picking the right harness or extension, send us your Propex model and a photo of your current thermostat connection.

How do I change the Propex digital thermostat between Fahrenheit and Celsius?

The Propex digital thermostat can show temperature in either Fahrenheit or Celsius.

Use the thermostat's temperature-setting controls to open the display setting and switch between °F and °C.

If you're not sure which thermostat version you have, send us a photo and we'll help.

What should I know about installing a Propex heater in an insulated floor?

This applies to interior-mounted HS2000 and HS2800 heaters. Thick, insulated floors need a little extra planning when routing the combustion pipes through the floor.

The combustion intake and exhaust connections are on the bottom of the heater. With a thick or insulated floor, the pipes may need to travel down through the flooring before turning toward the side of the vehicle.

Protect the combustion exhaust pipe where it passes through insulated flooring. Propex offers an insulated heat sleeve for this. It keeps the exhaust heat away from your insulation and flooring.

You may need to make the floor opening slightly larger to fit the heat sleeve. Seal the gap between the sleeve and the floor with a high-temperature gasket maker.

Since the flooring can hide the hose clamps that connect the combustion pipes to the heater, attach the pipes to the heater outlet stubs before mounting the heater. Otherwise you may have to remove the heater and pipes together for future service.

As with any Propex install, use a high-temperature RTV gasket maker at the ends of the combustion exhaust silicone connector and where the pipe exits the vehicle floor.

What are the rules for the combustion intake and exhaust pipes?
  • Never trim the pipes. Trimming upsets the combustion balance and causes malfunction or early failure.
  • The exhaust pipe needs a constant downward slope so condensation drains out instead of restricting airflow.
  • Keep the intake and exhaust ends at least 0.5 meters (1.5 ft) apart so exhaust isn't pulled back into the intake.
  • The exhaust must end past the outside edge of the vehicle and face toward the rear. Carbon monoxide is heavier than air and can pool under the vehicle, so poor routing risks CO coming in through the floor. We strongly recommend a CO detector.
Propex combustion pipe next to a tape measure showing the 40 inch minimum length

Minimum required pipe length: 1 meter (about 40 inches)

What should I know about protecting and routing the Propex exhaust?

The combustion intake and exhaust pipes are key to safe, proper heater operation. Route them carefully and keep them protected from damage, restrictions, and debris.

Do not shorten the combustion pipes. If you truly need more length, the pipes can be extended within the limits Propex specifies. Avoid unnecessary bends and secure the pipes so they can't move or get damaged.

Give the exhaust a slight downward slope so condensation drains away instead of collecting and restricting airflow.

Keep the intake and exhaust ends separated as required, and keep both clear of dirt, debris, and insects.

Propex combustion pipe end caps help keep bugs and debris out while the heater is off. Every so often, pull the caps, check the pipes for blockages, and put the caps back on.

If you suspect a blocked or damaged pipe, fix it before running the heater again. Unsure about your routing? Send us photos of the full intake and exhaust routing and we'll take a look.

How do I check or adjust the ignitor gap on an HS2211?

The ignitor gap can affect ignition on the HS2211. This procedure is for the HS2211 only.

Remove the screws holding the ignitor and carefully pull it out. Clean the ignitor tips if needed, then check the gap between them.

The gap should be 2 to 3 mm. Adjust carefully if needed, then reinstall the ignitor and screws.

After reassembly, check the propane connections for leaks with soapy water before running the heater.

If you're not comfortable with this, we recommend having a qualified technician handle it, or give us a call.

What should I know about installing hot air outlets?

Install hot air outlets at floor level. Heat rises, so floor-level outlets give you the most even, efficient warmth.

  • Maximum 3 hot air outlets per heater
  • Maximum length to the first outlet: 1.5 meters (4.5 ft)
  • Total combined cabin ducting must not exceed 5 meters (15 ft)
What is the Propex Stealth Kit, and what does it do?

The Propex Stealth Kit makes the HS2000 even quieter by reducing sound from the combustion intake and exhaust.

The kit includes intake and exhaust mufflers, acoustic ducting, and silicone connectors.

The HS2000 is already a quiet heater, but the Stealth Kit is a nice upgrade when you want it extra hushed.

Adding it to an existing HS2000? Make sure the parts are installed to the Propex routing requirements for the combustion intake and exhaust.

What should I know about the wiring connectors?

Good wiring connections are key to reliable heat. Protect the connectors from moisture and corrosion, especially where condensation is likely.

Before connecting, apply a small amount of dielectric grease to the female side of the connector. It protects against corrosion while still letting the connector seat properly.

Make sure connectors are fully seated and the wiring is secured so it can't be pulled, pinched, or damaged.

Troubleshooting an electrical issue? Check the wiring connections and 12V power supply before assuming the heater itself has failed.

What type of propane regulator should I use?

If your propane system uses a single-stage regulator, replace it with a two-stage regulator. A two-stage regulator holds more consistent pressure as elevation changes. Use an 11" water column regulator for efficient gas flow.

Note: A faulty regulator is one of the most common causes of Propex issues we see.

What type of propane fittings should I use?

⚠️ Important: The compression fitting supplied with the heater is BSPT thread, which is NOT the same as standard US 1/4" NPT. Do not substitute US NPT fittings or you will have a gas leak.

Alternate BSPT fittings can be sourced from McMaster-Carr, or give us a call and we'll help you find the right one.

What type of tubing should I use for the propane fuel line?

Use 1/4" copper tubing to run propane from the tank to the heater. The Propex compression fitting is designed to work directly with 1/4" OD copper tubing.

Need help planning your fuel line or sourcing parts? Call (970) 578-0791 or email support@mountaintimecampers.com.

Troubleshooting

Why does my Propex fan keep cycling on and off?

If your Propex fan starts and stops in roughly one-second bursts no matter the thermostat setting, we've seen this happen when the heater was started with a low battery.

The fan begins its normal pre-combustion purge but doesn't have enough battery charge to finish the cycle.

First, disconnect 12V power to the heater by pulling the inline fuse. Charge the battery, reconnect 12V power, and do a fault-code reset before starting the heater again.

If it keeps happening, disconnect 12V power again and leave the heater disconnected for 24 hours. Then reconnect, do a fault-code reset, and try again.

There's also a more advanced capacitive-discharge procedure that involves removing the main circuit board and leaving it disconnected for 24 to 48 hours. Only try this if you're comfortable working with electronics.

If a full capacitive discharge doesn't fix it, the main circuit board may need replacing. We offer heater service for board replacement, so just reach out.

What should I check if my Propex heater is not responding correctly?

Start with the heater's electrical connections and 12V power supply.

Confirm that 12V power is reaching the heater and that the ground is secure. Check both sides of the inline fuse with a multimeter to make sure power is passing through.

Check the wiring connectors closely. A wire can get pulled out of a connector during install, especially when routing the thermostat harness. Make sure connectors are fully seated and each wire is held in place.

Before disconnecting the thermostat or its connector, disconnect the heater from 12V power. You can then check the thermostat harness for continuity with an ohmmeter if needed.

Some Propex models have wires that are intentionally left unconnected. For example, the HS2211 has specific brown and red-striped white wires that aren't used in a standard install.

If you're unsure about your wiring, please don't guess. Send us photos of the heater wiring and connections along with your heater model, and we'll help with the next step.

How do I check or replace the Propex onboard fuse?

Propex heaters have an onboard 2A slow-blow fuse that protects the heater's electrical system.

Before working on the fuse or disconnecting the thermostat, disconnect the heater from 12V power.

On the HS2000 and HS2800, the fuse is behind the electrical access panel. On the HS2211, it's reached through the end cap.

If you suspect the fuse has failed, remove it and check it for continuity. Replace it only with the correct 2A slow-blow fuse.

Before reconnecting 12V power, make sure the thermostat is connected to the heater. Thermostat first, then power.

If the new fuse blows again, there may be an underlying electrical issue that needs diagnosing before you run the heater again. Give us a call and we'll help.

What should I check if my Propex heater has no flash code?

First, make sure the room temperature is below 80°F. The thermostat tops out around 80°F, and above that the heater won't call for heat.

If it's below 80°F and the heater still doesn't respond, disconnect the heater from 12V power and reconnect it. When power comes back, listen for the short fan cycle during startup.

If the fan doesn't run at all, check the 12V power supply and onboard fuse.

Also confirm the thermostat is connected correctly and its wiring is secure.

Still stumped? Send us your heater model and photos of the installation and wiring and we'll help figure it out.

How do I reset a Propex solid light lockout?

To reset a solid light lockout, disconnect the heater from 12V power and then reconnect it.

Before restoring power, make sure the thermostat is connected to the heater.

Once power is back, the heater should be ready to run. If it goes right back into a solid light lockout, keep troubleshooting the fault condition or give us a call.

What does a 1-flash Propex fault code mean?

A 1-flash fault code means flame failure. Start by resetting the heater, then check your propane supply.

Make sure the tank is turned on and has plenty of propane. Check the fittings and fuel system for obstructions or restrictions.

The propane regulator is especially worth checking. In our experience, it's one of the most common causes of 1-flash faults.

If the 1-flash fault continues after checking the propane supply and regulator, contact us and we'll keep troubleshooting with you.

What does a 2-flash Propex fault code mean?

A 2-flash fault code means the overheat sensor detected the heater getting too hot.

Let the heater cool and reset the fault. Then check the heated-air ducting and outlets for restrictions or blockages.

Route the heated-air ducting without sharp restrictions. Avoid tight duct angles and 90-degree fittings close to the heater outlet, since they can choke airflow and cause overheating.

If the 2-flash fault continues after checking the heated-air system, contact us for more help.

What does a 3-flash Propex fault code mean?

A 3-flash fault code means the heater is seeing voltage outside its normal range, either too low or too high.

Check the vehicle or auxiliary battery and make sure the heater is getting a stable 12V supply.

Charging systems can cause voltage spikes too. This is especially common with solar charging, which can push voltage above the heater's acceptable range.

Propex electronics have an upper voltage limit of about 15V. If your charging system can go higher, you may need an inline regulator or switch.

If the 3-flash fault continues after checking the power supply and charging system, contact us for more help.

What does a 4-flash Propex fault code mean?

A 4-flash fault code points to a problem with the combustion-air system.

Check both the combustion intake and exhaust pipes for blockages, damage, or restrictions. Make sure they're routed properly and their ends are clear.

Insects, rodents, dirt, and other debris can block the combustion piping and keep the heater from running right.

After checking the piping, reset the heater and try again. If the 4-flash fault comes back, contact us for more help.

What does a 5-flash Propex fault code mean?

A 5-flash fault code means the airflow sensor is reading something outside its expected range before the heater starts.

Check both combustion pipes and make sure they're about 1 meter long and routed correctly. Look for restrictions, kinks, damage, or blockages.

Insects, rodents, dirt, and other debris can block the combustion piping, so make sure both pipe ends are clear.

If you use compressed air to clear the pipes, stay under 30 PSI. Air pushed through the intake can come out the exhaust, so keep clear of the exhaust end.

After checking the piping, reset the heater and try again. If the 5-flash fault comes back, contact us for more help.

What is the Propex CN-18 reset procedure?

The CN-18 reset procedure is an extra circuit-board reset that can help when a heater keeps showing a 1-flash fault, or sometimes no flash code, after a normal fault-code reset.

Important: This requires access to the heater's electronics. Only do it if you're comfortable working around the heater's electrical connections.

With the heater powered, remove the electronics cover and find the CN-18 three-pin socket. Using an insulated jumper or similar tool, briefly connect the center pin to the pin closest to the thermostat connector.

Remove the jumper, then do the normal Propex fault-code reset.

If you're not comfortable with the electronics or unsure which pins to connect, please don't guess. Contact us and we'll help decide whether CN-18 is right for your heater.

How do I reset Propex fault codes?

When the heater runs into conditions outside its safe operating range, the circuit board may throw a fault code. To reset:

  1. Turn the thermostat temperature to full hot
  2. Turn the operation dial: OFF → FAN → FLAME
  3. Then back: FLAME → FAN → OFF
  4. Then again: OFF → FAN → FLAME

⚠️ Timing matters. Take about one second per step. Watch the fault code reset video on YouTube to get the timing right.


Mountain Time Campers is the home of Propex in North America, right here in Fort Collins, Colorado. For technical support, call (970) 578-0791 or email support@mountaintimecampers.com.

Back to top